IBM Webcam 4J Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Sporáky IBM Webcam 4J. IBM Webcam 4J User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - User Guide

Sterling Connect:Direct for UNIXUser GuideVe r s i o n 4 .1

Strany 2

enables you to edit the text of saved Processes, issue UNIX commands, and resolveProcess errors without exiting and reentering the CLI. Use the follow

Strany 3

Abbreviations for Common Sterling Connect:Direct CommandsThe following table lists valid abbreviations for commonly used parameters forSterling Connec

Strany 4

v When typing commands, type the entire command name or type the first threecharacters or abbreviate specific parameters. Refer to “Abbreviations forC

Strany 5 - Contents

Parameter Description Valuesclass The node-to-node session on which a Processcan execute. A Process can execute on the classspecified or any higher se

Strany 6

Parameter Description Valuesnotify The user e-mail to receive Process completionmessages. This parameter uses the rmail utilityavailable in the UNIX S

Strany 7 - CLI Commands

Parameter Description Valuessnode Identifies the name of the secondary node.Setting this value overrides the snode value inthe Process statement. The

Strany 8

Parameter Description Valuessnodeid Specifies security user IDs and securitypasswords on the SNODE. The snodeidsubparameters can contain one or moreal

Strany 9 - CLI Job Control

Parameter Description Valuesstartt Identifies the date, day, and time to start theProcess. Sterling Connect:Direct places theProcess in the Timer queu

Strany 10 - CLI History Commands

Parameter Description Valuestracel Specifies the level of trace to perform for aProcess. Tracing by Process can be turned on inthe submit command or a

Strany 11

Example - Submit a Process and Turn On TracingThe following command submits the Process named copy.cdp:submit file=copy.cdp tracel=4 pnode;Because tra

Strany 13

Parameter Description Valuesnode Locate the Process to bechanged by the secondarynode name. This parametercan be used to specify aspecific remote node

Strany 14

Parameter Description Valuehold Moves the Process to the Holdor Wait queue.yes | no | callyes—Places the Process in the Holdqueue in HO status until i

Strany 15

You select the Process to delete by Process name, Process number, secondary nodename, submitter, or any combination of the search criteria parameters.

Strany 16

The following command deletes all nonexecuting Processes submitted by user IDcduser on node dallas:delete process submitter=(dallas, cduser);Removing

Strany 17

Parameter Description Valuesubmitter Locate the Processes toremove by the nodespecification (the SterlingConnect:Direct nodename) and user ID of thePr

Strany 18

You can specify the force, immediate, quiesce, or step parameters with the stopcommand.Note: The force parameter is required when running Sterling Con

Strany 19 - Changing Process Parameters

Parameter Description Valuepname Locate the Process to viewby Process name.The Process name is limitedto 8 characters on SterlingConnect:Direct for Mi

Strany 20

Parameter Description Valuestatus Specifies the Processes to beviewed by Process status. Ifyou do not specify a statusvalue, information isgenerated f

Strany 21

Parameter Description Valuesubmitter Locate the Processes to viewby the node specification (theSterling Connect:Direct nodename) and user ID of thePro

Strany 22

Parameter Description Valuequeue Specifies the Processes to beselected by the specifiedqueue names. The default isall.all | exec | hold | wait | timer

Strany 23

Sterling Connect:Direct for UNIXUser GuideVe r s i o n 4 .1

Strany 24

Parameter Description Valuestatus Specifies the Processes to beselected by Process status. Ifyou do not specify a statusvalue, information isgenerated

Strany 25 - Viewing a Process in the TCQ

Parameter Description Valuesubmitter Locate the Processes toselect by the nodespecification (the SterlingConnect:Direct node name)and user ID of the P

Strany 26

Determining the Outcome of a ProcessThe select statistics command is used to examine Process statistics from theSterling Connect:Direct statistics fil

Strany 27

Parameter Description Valuepname Locate the statistics toselect by Process name.The Process name islimited to 8 characters onSterling Connect:Directfo

Strany 28

Parameter Description ValueCTRM—Child Process terminated.CUKN—Child Process unknown status.CXIT—Child Process exited.DELP—The delete Process command i

Strany 29

Parameter Description ValuePSTR—Process started.QCEX—A Process moved from another queue tothe EXEC queue.QCWA—A Process moved from another queue tothe

Strany 30

Parameter Description ValueUNKN—Unknown command issued.USEC—Security check for user ID failed.USMG—Sterling Connect:Direct is shuttingdown.XCMM—Comman

Strany 31

Parameter Description Valuesnode Locate the statistics filerecord by the secondarynode name. Thisparameter can be used tospecify a specific remotenode

Strany 32

Parameter Description Valuestopt Specifies that SterlingConnect:Direct searchesfor statistics records up toand including thedesignated date, day, andt

Strany 33

Generating a Summary Report for a ProcessYou can use the select statistics command to generate a summary report for aProcess. The following command ge

Strany 34

NoteBefore using this information and the product it supports, read the information in “Notices” on page 83.This edition applies to version 4.1 of IBM

Strany 35

Parameter Description Valuecmgr To trace the CommandManager.level=0 |1|2|4file=namelevel—Specifies the level of detail displayed inthe trace output. T

Strany 36

Parameter Description Valuepmgr To trace the ProcessManager.level=0 |1|2|4file=namelevel—Specifies the level of detail displayed inthe trace output. T

Strany 37

trace smgr pnode tnode=ath3500ry level=2 file=Smgp.trc;A partial sample trace output is illustrated in the following section. A traceidentifies the Pr

Strany 38

Chapter 2. Process QueuingOverview of the Transmission Control QueueThe TCQ controls Process execution as Sterling Connect:Direct operates. After yous

Strany 39 - Running System Diagnostics

SchedulingParameter Queue Commentsretain=initial Hold A copy of the Process remains in the Hold queueand executes every time the Process Manager isini

Strany 40

The Execution QueueProcesses are placed in the Execution queue after Sterling Connect:Direct connectsto the remote node. Processes normally come from

Strany 41

After a Process successfully completes, it is automatically deleted from theExecution queue. A flush process command with hold=yes moves a Process fro

Strany 42

The Timer QueueProcesses are placed in the Timer queue by a submit command with the starttparameter specified. Processes in the Wait for Start Time (W

Strany 43 - Chapter 2. Process Queuing

Processes are placed in the Hold queue by a submit command with retain=initial,retain=yes, or hold=yes parameters specified. Processes submitted with

Strany 44

Chapter 3. Sterling Connect:Direct UtilitiesIntroduction to Translation TablesSterling Connect:Direct translates data from one character set code to a

Strany 45 - The Execution Queue

ContentsChapter 1. Controlling and MonitoringProcesses ...1Overview of the Command Line Interface ...1Starting the CLI ...1Stoppi

Strany 46 - The Wait Queue

Compiling a Translation Table Using the ndmxlt UtilityBefore you beginYou can create or modify a translation table tailored to your requirements with

Strany 47 - The Hold Queue

3. Add the following lines to the bottom of the table. It should look like the tablein “Creating a Translation Table” on page 43when you have added th

Strany 48

To specify a customized table for data translation, include the following sysoptssubparameter in the copy statement, where pathname/filename identifie

Strany 49 - Creating a Translation Table

xxx is a 3-character Sterling Connect:Direct component identifiernnn is a 3-digit decimal numberI is the standard, though not required, suffixMessage

Strany 50 - Procedure

short.text=CMGR RPC call returns NULLlong.text=The ndmapi_sendcmd RPC call made by the API to the CMGR returns aNULL pointer.There is probably an RPC

Strany 51

Using the Standalone Batch Compression UtilityBefore you beginTo invoke the standalone batch compression utility (cdsacomp), type the followingcommand

Strany 52 - Message File Content

Parameter Description Values-p Use this option to specify codepages forfile conversion. Default is no codepagetranslation.This parameter is mutually e

Strany 53 - Displaying Message Text

Parameter Description Values-a Use this option to replace zero-lengthrecords with a single, blank character.This parameter is valid only when youspeci

Strany 54 - Compression Utility

cdsacomp -m decompress-d text-i compressed.file-o dest.file-x /home/cd/ndm/xlate/def_recv.xltExamples—csdacomp Command HelpRequesting a summary of cds

Strany 55

Validate Configuration FilesWhen you manually edit any of the five text-based Sterling Connect:Directconfiguration files, the Configuration Checking U

Strany 56

iv Sterling Connect:Direct for UNIX: User Guide

Strany 57

v Sterling Connect:Direct Secure Plus for UNIXv Sterling Connect:Direct for SWIFTNet for UNIXDuring the Sterling Connect:Direct installation, cdcustrp

Strany 58 - Precompressed

################################################################################## Connect:Direct for UNIX 4.0.00 configuration report ###############

Strany 59 - Configuration Reports

The following example shows an excerpt from a sample report:===== Begin: Secure+ parameters ==============================================All secure+

Strany 60

Log.MaxVersions="5"[connection.info]# Connection information for Connect:Direct’s API port. (Used when forwarding filesto the back office.)C

Strany 61 - Secure Plus for UNIX

58 Sterling Connect:Direct for UNIX: User Guide

Strany 62

Chapter 4. Writing Custom ProgramsIntroduction to Writing Custom ProgramsThe Sterling Connect:Direct Application Programming Interface (API) allows yo

Strany 63

Platform C++ Compile Command64-bit /opt/SUNWspro/bin/CC -xarch=generic64 -DBSD_COMP -I../include -o sdksample sdksample.C../lib/ndmapi64.a-L/usr/ucbli

Strany 64

Platform C Compile CommandHP32-bit /opt/ansic/bin/cc -I../include -o apicheck apicheck.c ../lib/ndmapi.a -lrpcsoc -lnsl -ldld -Wl,+s -lcl-lstd_v2 -lCs

Strany 65 - Compiling Custom Programs

C++ Function C Function Descriptionndmapi_sendcmd() ndmapi_sendcmd_c() Sends commands to Sterling Connect:Direct.You must provide the command text. Th

Strany 66

from the commands. Control returns to the application when the connection isestablished and Sterling Connect:Direct is ready for the first API request

Strany 67 - Writing Custom C Programs

Chapter 1. Controlling and Monitoring ProcessesOverview of the Command Line InterfaceThe Command Line Interface (CLI) enables you to submit Sterling C

Strany 68

Receiving Responses Using ndmapi_recvresp() orndmapi_recvresp_c()Use ndmapi_recvresp() or ndmapi_recvresp_c() to receive responses that areassociated

Strany 69

Parameter Description ValueDDS1—Destination disposition 1DDS2—Destination disposition 2DDS3—Destination disposition 3DESC—Sterling Connect:Directadmin

Strany 70

Parameter Description ValuePNOD—PNODEPNUM—Process numberPPMN—PDS member namePRTY—PriorityQUEU—QueueRECC—Record categoryRECI—Record IDRETA—Retain Proce

Strany 71

Parameter Description ValueSTAT—Process statusSNOD—SNODESNVL—Source number ofvolumesSOPT—SYSOPTS recordSRCR—Records readSRUX—RUs sentSTIM—Schedule tim

Strany 72

Sending a Command to Sterling Connect:Direct Usingndmapi_sendcmd() or ndmapi_sendcmd_c()Use ndmapi_sendcmd() or ndmapi_sendcmd_c() to allow a command

Strany 73

Parameter Description Valuecmd_id A four-byte identifier of the command that was found inthe command text. Following are the four-byteidentifiers:/***

Strany 74

Note: The environment variable NDMAPICFG must be set to the pathname of theclient configuration file. Refer to “Starting the CLI” on page 1for instruc

Strany 75 - Writing Custom C++ Programs

Method Description Parameter Return ValuesConnect Provides a connection to theSterling Connect:Direct server.Connect() with a void parameterconnects t

Strany 76

Method Description Parameter Return ValuesGetPreviousError Moves the error data pointer tothe previous error in the list.void TRUE—If successfulFALSE—

Strany 77

// Methods for retrieving ReceiveResponse data...virtual const char *GetResponse(void) = 0;virtual int GetResponseLength(void) = 0;virtual bool MoreDa

Strany 78

Option Description ValueSample CommandEntry-P Identifies the custom string touse at the command lineprompt.If the prompt string includesspaces or spec

Strany 79

74 Sterling Connect:Direct for UNIX: User Guide

Strany 80

Chapter 5. Writing User ExitsUser Exit ProgramsThe user exit API functions allow you to write custom programs to use withSterling Connect:Direct. The

Strany 81 - Chapter 5. Writing User Exits

C++ Function C Function Descriptionexit_child_init() exit_child_init_c() Use this function as the first line in a user exitprogram to initialize commu

Strany 82

Waiting for a Message Using recv_exit_msg() orrecv_exit_msg_c()The recv_exit_msg() or recv_exit_msg_c() function waits until it receives a messagefrom

Strany 83

The send_exit_file() or send_exit_file_c() function calls have the following returncodes. Return codes for the function are defined in ndmapi.h.Header

Strany 84

Overview of User Exit MessagesSterling Connect:Direct sends and receives messages, using the send_exit_msg()and the recv_exit_msg() functions for a C+

Strany 85 - File Open Exit Messages

v UNIX user namev A copy of the Sterling Connect:Direct copy control blockv A copy of the Sterling Connect:Direct parsed sysopts structure (the copy c

Strany 86 - Security Exit Messages

v VALIDATE_MSGv VALIDATE_REPLY_MSGCAUTION:If the security exit is used, Sterling Connect:Direct relies on it for user IDauthentication. If the securit

Strany 87 - VALIDATE_MSG

VALIDATE_REPLY_MSGThe user exit program sends a reply message to the Sterling Connect:DirectVALIDATE_MSG. The VALIDATE_REPLY_MSG contains:v Status val

Strany 88 - Exit Log Files

NoticesThis information was developed for products and services offered in the U.S.A.IBM may not offer the products, services, or features discussed i

Strany 89

Option Description ValueSample CommandEntry-e nn Defines the error level abovewhich the CLI automaticallyexits. If the returned error codeis greater t

Strany 90

incorporated in new editions of the publication. IBM may make improvementsand/or changes in the product(s) and/or the program(s) described in thispubl

Strany 91 - Trademarks

This information is for planning purposes only. The information herein is subject tochange before the products described become available.This informa

Strany 92

Microsoft, Windows, Windows NT, and the Windows logo are trademarks ofMicrosoft Corporation in the United States, other countries, or both.ITIL is a r

Strany 93

IndexSpecial characters-e nn parameter, direct command 3-h parameter, for direct 3-n name parameter, direct command 3-p nnnnn parameter, direct comman

Strany 94

Iinformational responses, API 62Initializing communications using userexit functions 76Llogfile parameterexit_child_init() function 76MManaging Proces

Strany 95

User Exit Stop Message (continued)STOP_MSG 82Using the Stand-alone Batch CompressionUtility 49Using translation during file transferoperationg 45Utili

Strany 96

90 Sterling Connect:Direct for UNIX: User Guide

Strany 98 - Printed in USA

Product Number: 5725-C99Printed in USA

Komentáře k této Příručce

Žádné komentáře